In vivo strain measurements in the human buttock during sitting using MR-based digital volume correlation

Zappalá, Stefano, Keenan, Bethany E. ORCID: https://orcid.org/0000-0001-7787-2892, Marshall, David ORCID: https://orcid.org/0000-0003-2789-1395, Wu, Jing ORCID: https://orcid.org/0000-0001-5123-9861, Evans, Sam L. ORCID: https://orcid.org/0000-0003-3664-2569 and Al-Dirini, Rami M.A. 2024. In vivo strain measurements in the human buttock during sitting using MR-based digital volume correlation. Journal of Biomechanics 163 , 111913. 10.1016/j.jbiomech.2023.111913

[thumbnail of 1-s2.0-S0021929023004840-main.pdf] PDF - Published Version
Available under License Creative Commons Attribution.

Download (6MB)

Abstract

Advancements in systems for prevention and management of pressure ulcers require a more detailed understanding of the complex response of soft tissues to compressive loads. This study aimed at quantifying the progressive deformation of the buttock based on 3D measurements of soft tissue displacements from MR scans of 10 healthy subjects in a semi-recumbent position. Measurements were obtained using digital volume correlation (DVC) and released as a public dataset. A first parametric optimisation of the global registration step aimed at aligning skeletal elements showed acceptable values of Dice coefficient (around 80%). A second parametric optimisation on the deformable registration method showed errors of and against two simulated fields with magnitude and , respectively, generated with a finite element model of the buttock under sitting loads. Measurements allowed the quantification of the slide of the gluteus maximus away from the ischial tuberosity (IT, average 13.74 mm) that was only qualitatively identified in the literature, highlighting the importance of the ischial bursa in allowing sliding. Spatial evolution of the maximus shear strain on a path from the IT to the seating interface showed a peak of compression in the fat, close to the interface with the muscle. Obtained peak values were above the proposed damage threshold in the literature. Results in the study showed the complexity of the deformation of the soft tissues in the buttock and the need for further investigations aimed at isolating factors such as tissue geometry, duration and extent of load, sitting posture and tissue properties.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Computer Science & Informatics
Cardiff University Brain Research Imaging Centre (CUBRIC)
Publisher: Elsevier
ISSN: 0021-9290
Date of First Compliant Deposit: 5 January 2024
Date of Acceptance: 20 December 2023
Last Modified: 05 Jan 2024 10:15
URI: https://orca.cardiff.ac.uk/id/eprint/165053

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics