Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

The robustness of various forms of perimetry to different levels of induced intraocular stray light

Anderson, R. S., Redmond, Tony ORCID: https://orcid.org/0000-0002-6997-5231, McDowell, D. R., Breslin, K. M. M. and Zlatkova, M. B. 2009. The robustness of various forms of perimetry to different levels of induced intraocular stray light. Investigative Ophthalmology & Visual Science 50 (8) , pp. 4022-4028. 10.1167/iovs.08-2934

[thumbnail of Anderson 2009.pdf]
Preview
PDF - Published Version
Download (343kB) | Preview

Abstract

purpose. To compare directly the robustness of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), frequency-doubling perimetry (FDP), and grating-resolution perimetry (GRP) stimuli to different degrees of intraocular stray light induced by commercially available opacity-containing filters. methods. Five white opacity filters of increasing density were used to simulate the typical forward light scatter and stray light values associated with age-related lens opacification and significant cataract. The individually induced intraocular stray light value for each filter was quantified with a stray light meter and plotted against individual perimetric thresholds for the right eyes of three normally sighted trained observers for SAP, SWAP, FDP, and GRP. results. All tests were significantly but differently affected by increasing stray light. Overall average declines over a 1 log unit change in the stray light values were as follows: SAP, 4.85 dB; SWAP, 9.03 dB; FDP, 4.29 dB; and GRP, 1.36 dB. Standardized (z) scores were calculated after normalization to the spread of the normative data values for each instrument. These indicated that the standardized changes from baseline over the range of the five filters per log stray light unit were as follows: SAP, 2.177; SWAP, 1.96; FDP, 1.277; and GRP, 1.04. conclusions. The increased stray light values induced by cataract-simulating filters has a significant effect on all tests. However, GRP, which is known to be limited by retinal sampling rather than contrast, remains the most robust of the tests to the effects of intraocular stray light. The degree to which the normative “sensitivity” range for different types of perimetry might incorporate a component caused by individual differences in intraocular stray light is discussed and requires further research.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Optometry and Vision Sciences
Subjects: R Medicine > RE Ophthalmology
Additional Information: Confirmation received by publisher on 21 February 2014 that publisher's pdf can be self-archived 6 months after publication.
Publisher: Association for Research in Vision and Ophthalmology
ISSN: 0146-0404
Date of First Compliant Deposit: 30 March 2016
Last Modified: 23 May 2023 19:25
URI: https://orca.cardiff.ac.uk/id/eprint/36750

Citation Data

Cited 13 times in Scopus. View in Scopus. Powered By Scopus® Data