Analysis of retinal image quality for peripheral vision in humans and pigeons (Columba livia)

Garcia Sanchez, Yaiza 2012. Analysis of retinal image quality for peripheral vision in humans and pigeons (Columba livia). PhD Thesis, Cardiff University.
Item availability restricted.

[thumbnail of SanchezYG.pdf] PDF - Supplemental Material
Restricted to Repository staff only

Download (75kB)
[thumbnail of Garcia Sanchez - Zaiza FINAL (1) dec page removed.pdf]
Preview
PDF - Accepted Post-Print Version
Download (41MB) | Preview

Abstract

Retinal image quality for peripheral as well as central visual field locations has been investigated in humans and an animal model (Columba livia) with wide- angle, panoramic vision because of its laterally oriented eyes. The goal was to determine whether the retinal image is maintained at a higher quality away from the fovea in pigeons as compared to humans. In this thesis, the HSWFS (Hart- mann Shack Wavefront Sensor) has been implemented with the correspondent validation and application for measuring ocular aberrations in the human and avian eye.
Using a modified HSWFS, the refractive error and total amount of ocular aberra- tions were measured for 20 pigeons along the horizontal meridian and for another 8 pigeons in the vertical meridian at three positions along the horizontal meridian. The HOA( High order aberrations) of 10 humans were measured at peripheral locations (±35 ◦) in the upper visual field and along the horizontal meridian. The anaesthetized animal’s head position was controlled by a stereotaxic head holder capable of horizontal and vertical rotation. Measured eccentricities were(±60◦) from the fovea in the horizontal meridian and +35 ◦ and -25 ◦ along each of the three vertical meridians. In pigeons, the LOA (astigmatism) on the horizontal meridian increase slightly from the center towards the far periphery but are relatively constant for ±20◦ around the fovea, whereas defocus remains almost constant. Vertical meridian measurements are consistent with the previously reported myopia in the lower visual field. Compared with measurements in human subjects, the overall values of RMS are much lower in the pigeon at all corresponding eccentricities. Off-axis vision is generally dominated by defocus and astigmatism. In pigeons, however, defocus along the horizontal meridian does not change dramatically whereas, along the vertical meridian, the presence of a lower field myopia is confirmed. Astigmatism of the eye for increasing eccentricity (horizontally and vertically) is consistently lower then expected theoretically and when compared with humans. This demonstrates that the visual optics of the pigeon are more fully corrected for peripheral vision than in humans.

Item Type: Thesis (PhD)
Status: Unpublished
Schools: Optometry and Vision Sciences
Subjects: R Medicine > RE Ophthalmology
Uncontrolled Keywords: Peripheral Vision, pigeon, ocular aberrations, visual optics