Pharmacokinetics of recombinant factor VIII (recombinate) using one-stage clotting and chromogenic factor VIII assay

Lee, C. A., Owens, D., Bray, G., Giangrande, P., Collins, Peter William ORCID: https://orcid.org/0000-0002-6410-1324, Hay, C., Gomperts, E., Schroth, P. and Barrowcliffe, T. 1999. Pharmacokinetics of recombinant factor VIII (recombinate) using one-stage clotting and chromogenic factor VIII assay. Thrombosis and Haemostasis 82 (6) , pp. 1644-1647.

Full text not available from this repository.

Abstract

In a study designed to demonstrate the safety and pharmacokinetics of a recombinant factor VIII (Recombinate) manufactured in Andover, MA and Thousand Oaks, CA, two different methods of factor VIII assay (one-stage clotting and Chromogenic substrate) were compared in vivo. The study was performed in four centres in the UK: London, Oxford, Cardiff and Manchester. Two pharmacokinetic studies, at least one week apart, were performed in 30 patients with severe haemophilia A (VIII:C < 2 IU/dl). A dose of 50 IU/kg was administered with sampling pre-infusion, and +0.25, 0.5, 1, 3, 6, 9, 12 and 24 h post-infusion. The aggregate 60 pharmacokinetic study showed a half-life of 12.7 and 13.0 h (p = 0.28) and recovery of 127 and 161 IU/dl (p = 0.0001) using one-stage clotting or chromogenic substrate respectively. In a supplementary experiment, 20 post-infusion samples were re-assayed by 1-stage and chromogenic assay using two plasma (20 th British plasma standard and an “in-house” pooled normal plasma) and two concentrate standards, derived from the same type, but different batch of infused concentrate (Recombinate) and pre-diluted in either individual pre-infusion sample or in pooled commercial haemophilic plasma. The use of the Recombinate concentrate standard overcame the significant difference in FVIII levels between 1-stage and chromogenic assay methods when a plasma standard was used (p <0.0001). It is concluded that where potency dosing designation is carried out by an assay system different to that used in the clinical situation, the use of the recombinant concentrate as a standard in post-infusion plasma samples is likely to give more reliable and reproducible results.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Systems Immunity Research Institute (SIURI)
Subjects: R Medicine > R Medicine (General)
Publisher: Schattauer
ISSN: 0340-6245
Last Modified: 25 Oct 2022 10:13
URI: https://orca.cardiff.ac.uk/id/eprint/61449

Citation Data

Cited 60 times in Scopus. View in Scopus. Powered By Scopus® Data