Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Superiority of deformable image co-registration in the integration of diagnostic positron emission tomography-computed tomography to the radiotherapy treatment planning pathway for oesophageal carcinoma

Ward, G., Ramasamy, S., Sykes, J.R., Prestwich, R., Chowdhury, F., Scarsbrook, A., Murray, P., Harris, K., Crellin, A., Hatfield, P., Sebag-Montefiore, D., Spezi, Emiliano ORCID: https://orcid.org/0000-0002-1452-8813, Crosby, T. and Radhakrishna, G. 2016. Superiority of deformable image co-registration in the integration of diagnostic positron emission tomography-computed tomography to the radiotherapy treatment planning pathway for oesophageal carcinoma. Clinical Oncology 28 (10) , pp. 655-662. 10.1016/j.clon.2016.05.009

[thumbnail of Whole_manuscript_December_2015_including_figures_and_references.pdf]
Preview
PDF - Accepted Post-Print Version
Download (788kB) | Preview

Abstract

Aims To investigate the use of image co-registration in incorporating diagnostic positron emission tomography-computed tomography (PET-CT) directly into the radiotherapy treatment planning pathway, and to describe the pattern of local recurrence relative to the PET-avid volume. Materials and methods Fourteen patients were retrospectively identified, six of whom had local recurrence. The accuracy of deformable image registration (DIR) and rigid registration of the diagnostic PET-CT and recurrence CT, to the planning CT, were quantitatively assessed by comparing co-registration of oesophagus, trachea and aorta contours. DIR was used to examine the correlation between PET-avid volumes, dosimetry and site of recurrence. Results Positional metrics including the dice similarity coefficient (DSC) and conformity index (CI), showed DIR to be superior to rigid registration in the co-registration of diagnostic and recurrence imaging to the planning CT. For diagnostic PET-CT, DIR was superior to rigid registration in the transfer of oesophagus (DSC = 0.75 versus 0.65, P < 0.009 and CI = 0.59 versus 0.48, P < 0.003), trachea (DSC = 0.88 versus 0.65, P < 0.004 and CI = 0.78 versus 0.51, P < 0.0001) and aorta structures (DSC = 0.93 versus 0.86, P < 0.006 and CI = 0.86 versus 0.76, P < 0.006). For recurrence imaging, DIR was superior to rigid registration in the transfer of trachea (DSC = 0.91 versus 0.66, P < 0.03 and CI = 0.83 versus 0.51, P < 0.02) and oesophagus structures (DSC = 0.74 versus 0.51, P < 0.004 and CI = 0.61 versus 0.37, P < 0.006) with a non-significant trend for the aorta (DSC = 0.91 versus 0.75, P < 0.08 and CI = 0.83 versus 0.63, P < 0.06) structure. A mean inclusivity index of 0.93 (range 0.79–1) showed that the relapse volume was within the planning target volume (PTVPET-CT); all relapses occurred within the high dose region. Conclusion DIR is superior to rigid registration in the co-registration of PET-CT and recurrence CT to the planning CT, and can be considered in the direct integration of PET-CT to the treatment planning process. Local recurrences occur within the PTVPET-CT, suggesting that this is a suitable target for dose-escalation strategies.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Subjects: T Technology > TJ Mechanical engineering and machinery
Publisher: Elsevier
ISSN: 0936-6555
Date of First Compliant Deposit: 10 June 2016
Date of Acceptance: 4 May 2016
Last Modified: 15 Nov 2023 17:15
URI: https://orca.cardiff.ac.uk/id/eprint/91525

Citation Data

Cited 10 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics