Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Evaluation of the clinical effectiveness of fluocinolone acetonide 190 µg intravitreal implant in diabetic macular edema: a comparison between study and fellow eyes

Currie, Craig J., Holden, Sarah E., Berni, Ellen and Owens, David R. 2017. Evaluation of the clinical effectiveness of fluocinolone acetonide 190 µg intravitreal implant in diabetic macular edema: a comparison between study and fellow eyes. Current Medical Research and Opinion 33 (S2) , pp. 19-31. 10.1080/03007995.2017.1366659

Full text not available from this repository.

Abstract

Objectives: To compare visual and anatomical outcomes between eyes treated with fluocinolone acetonide (FAc) 190 µg intravitreal implant for clinically significant chronic diabetic macular edema (DME) and fellow eyes not treated with FAc implant using data from the Iluvien Clinical Evidence study in the UK (ICE-UK) study. Methods: In this retrospective cohort study, data on people attending hospital eye services and treated with the FAc implant between April 1, 2013 and April 15, 2015 were collected. Changes in visual acuity (VA), central foveal thickness (CFT) and intraocular pressure (IOP) were compared between study eyes (intervention) and fellow eyes. Results: A total of 208 people were selected. Mean age was 68.1 years and 62% were male. Mean change in VA was −0.09 LogMAR units for study eyes and 0.04 LogMAR units for fellow eyes at 12 months post-implant (p < .001). Over the same period, ≥5 letter, ≥10 letter and ≥15 letter improvements in Early Treatment Diabetic Retinopathy Study (ETDRS) score were achieved by more FAc treated eyes than by fellow eyes (41% versus 23%, p < .001; 28% versus 11%, p < .001; and 18% versus 4%, p < .001 at 12 months, respectively). Differences in the mean change in CFT (−113 µm versus −13 µm, p < .001) and IOP (3.2 mmHg versus −0.2 mmHg, p < .001) were also observed between study and fellow eyes at 12 months. Conclusion: Visual acuity improved in study eyes over the 12 months following FAc implant and worsened in fellow eyes. Over the same period, study eyes showed a larger improvement in central foveal thickness. Intraocular pressure worsened in study eyes only. Change in visual acuity, central foveal thickness and intraocular pressure between FAc implant and the end of the 12-month follow-up period differed significantly between study and fellow eyes.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Subjects: R Medicine > R Medicine (General)
Publisher: Informa Healthcare
ISSN: 0300-7995
Last Modified: 21 Feb 2022 09:46
URI: https://orca.cardiff.ac.uk/id/eprint/105810

Citation Data

Cited 13 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item