Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Novel Confocal-Laser-Scanning-Microscopy and conventional measures investigating eroded dentine following dentifrice dab-on and brushing abrasion

Olley, Ryan ORCID: https://orcid.org/0000-0003-1257-6835, Alhaij, Sana, Mohsen, Basim M, Appleton, Paul L, Chadwick, R Graham and Ball, Graeme 2020. Novel Confocal-Laser-Scanning-Microscopy and conventional measures investigating eroded dentine following dentifrice dab-on and brushing abrasion. Heliyon 6 (3) , e03282. 10.1016/j.heliyon.2020.e03282

[thumbnail of Olley 2020 Dentine wear Brushing Acid Rapid Relief - Copy.pdf] PDF - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (795kB)

Abstract

Objectives To validate novel non-contacting Confocal-Laser-Scanning-Microscopy (CLSM) methodology with conventional Contacting Profilometry (CP) measures investigating brushing or dab-on of stannous-fluoride dentifrice on early aggressive dentine erosion. Methods 75 polished human dentine samples were prepared and eroded in agitated 6% citric acid then randomly allocated into 5 intervention groups; artificial saliva control (1); controlled use of a pressure sensitive counter-rotating oscillatory powered toothbrush with sodium-fluoride NaF (2) or stannous-fluoride SnF2 (3), and dab-on application of NaF (4) or SnF2 (5). Samples underwent three cycles of intervention and 2-min agitated 6 % citric acid challenges. CLSM images were taken and 3D reconstructions produced of step height using a developed software algorithm. In addition, 20 % samples were randomised and profiled using CP to measure step height and surface roughness. Vickers's diamond micro-hardness testing was carried out on all samples. Results Comparing CLSM and CP; Pearson correlation was 0.77 and Intra-class correlation 0.81 (p = 0.01). There were no significant statistical differences in step height between groups using both CLSM and CP. From baseline, SnF2 brushing (3) increased micro-hardness more than control (1) (p = 0.03), NaF (4) and SnF2 dab-on (5) (p ≤ 0.001), and increased surface roughness more than control (p = 0.02), NaF brushing (2) and NaF dab-on (4) (p ≤ 0.017). Dab-on of SnF2 (5) produced rougher surfaces than control (1) (p = 0.014) and reduced hardness compared with NaF brushing (p = 0.04). Conclusions Good agreement and correlation exists between CLSM and CP measures in dentine. There were no significant differences in surface loss after interventions between groups. Compared with control, SnF2 application increased dentine surface roughness and SnF2 controlled powered brushing application increased dentine hardness, likely caused by exposure of uneroded dentine. Clinical significance Isosurfaces produced using CLSM can be used to represent dentine step height loss. They show good correlation and agreement with conventional CP measures, following early aggressive erosion-abrasion cycles of dentine. The CLSM and computer algorithm therefore provides an accurate, standalone and non-contacting three-dimensional measurement of early dentine wear. Stannous-fluoride brushing, and dab-on application offer no benefits following early aggressive erosion in dentine. To reduce dentine wear, limiting erosive challenges and avoiding brushing post-erosion is advised.

Item Type: Article
Date Type: Published Online
Status: Published
Schools: Dentistry
ISSN: 2405-8440
Date of First Compliant Deposit: 1 June 2020
Date of Acceptance: 20 January 2020
Last Modified: 05 May 2023 09:52
URI: https://orca.cardiff.ac.uk/id/eprint/132072

Citation Data

Cited 2 times in Scopus. View in Scopus. Powered By Scopus® Data