Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Global intravascular and local hyperoxia contrast phase-based blood oxygenation measurements

Driver, Ian D. ORCID: https://orcid.org/0000-0001-6815-0134, Wharton, Samuel J., Croal, Paula L., Bowtell, Richard, Francis, Susan T. and Gowland, Penny A. 2014. Global intravascular and local hyperoxia contrast phase-based blood oxygenation measurements. NeuroImage 101 , pp. 458-465. 10.1016/j.neuroimage.2014.07.050

[thumbnail of Driver. Global intravascular.pb.pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution.

Download (704kB) | Preview

Abstract

The measurement of venous cerebral blood oxygenation (Yv) has potential applications in the study of patient groups where oxygen extraction and/or metabolism are compromised. It is also useful for fMRI studies to assess the stimulus-induced changes in Yv, particularly since basal Yvpartially accounts for inter-subject variation in the haemodynamic response to a stimulus. A range of MRI-based methods of measuring Yv have been developed recently. Here, we use a method based on the change in phase in the MR image arising from the field perturbation caused by deoxygenated haemoglobin in veins. We build on the existing phase based approach (Method I), where Yvis measured in a large vein (such as the superior sagittal sinus) based on the field shift inside the vein with assumptions as to the vein's shape and orientation. We demonstrate two novel modifications which address limitations of this method. The first modification (Method II), maps the actual form of the vein, rather than assume a given shape and orientation. The second modification (Method III) uses the intra and perivascular phase change in response to a known change in Yvon hyperoxia to measure normoxic Yv in smaller veins. Method III can be applied to veins whose shape, size and orientation are not accurately known, thus allowing more localised measures of venous oxygenation. Results demonstrate that the use of an overly fine spatial filter caused an overestimation in Yv for Method I, whilst the measurement of Yv using Method II was less sensitive to this bias, giving Yv = 0.62 ± 0.03. Method III was applied to mapping of Yv in local veins across the brain, yielding a distribution of values with a mode of Yv = 0.661 ± 0.008.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Cardiff University Brain Research Imaging Centre (CUBRIC)
Psychology
Publisher: Elsevier
ISSN: 1053-8119
Date of First Compliant Deposit: 4 September 2018
Date of Acceptance: 24 July 2014
Last Modified: 02 May 2023 12:49
URI: https://orca.cardiff.ac.uk/id/eprint/64953

Citation Data

Cited 9 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics